World Journal of Emergency Medicine ›› 2011, Vol. 2 ›› Issue (3): 165-168.doi: 10.5847/wjem.j.1920-8642.2011.03.001
• Review Article • Next Articles
Open Access Received:2011-02-10
Accepted:2011-07-16
Online:2020-12-24
Published:2011-09-15
Contact:
Jin-song Zhang
E-mail:zhangjso@sina.com
Lei Jiang, Jin-song Zhang. Mechanical cardiopulmonary resuscitation for patients with cardiac arrest[J]. World Journal of Emergency Medicine, 2011, 2(3): 165-168.
Add to citation manager EndNote|Ris|BibTeX
URL: http://wjem.com.cn/EN/10.5847/wjem.j.1920-8642.2011.03.001
| 1 |
Varon J, Marik PE and Fromm RE. Cardiopulmonary resuscitation: a review for clinicians. Resuscitation 1998; 36:133-145.
doi: 10.1016/s0300-9572(98)00002-1 pmid: 9571729 |
| 2 |
Atwood C, Eisenberg MS, Herlitz J, Rea TD. Incidence of EMS- treated out-of-hospital cardiac arrest in Europe. Resuscitation 2005; 67:75-80.
doi: 10.1016/j.resuscitation.2005.03.021 pmid: 16199289 |
| 3 |
Lloyd-Jones D, Adams RJ, Brown TM, Carnethon M, Dai S, De Simone G, et al. Executive summary: heart disease and stroke statistics--2010 update: a report from the American Heart Association. Circulation 2010; 121:948-954.
doi: 10.1161/CIRCULATIONAHA.109.192666 pmid: 20177011 |
| 4 |
Slonim AD, Patel KM, Ruttimann UE, Pollack MM. Cardiopulmonary resuscitation in pediatric intensive care units. Crit Care Med 1997; 25:1951-1955.
pmid: 9403741 |
| 5 |
Axelsson C, Karlsson T, Axelsson AB, Herlitz J. Mechanical active compression-decompression cardiopulmonary resuscitation (ACD-CPR) versus manual CPR according to pressure of end tidal carbon dioxide (PET CO2) during CPR in out-of-hospital cardiac arrest (OHCA). Resuscitation 2009; 80:1099-1103.
doi: 10.1016/j.resuscitation.2009.08.006 pmid: 19716640 |
| 6 |
Moreno RP, Vassallo JC, Sáenz SS, Blanco AC, Allende D, Araguas JL, et al. Cardiopulmonary resuscitation in nine pediatric intensive care units of the Argentine Republic. Arch Argent Pediatr 2010; 108:216-225.
doi: 10.1590/S0325-00752010000300007 pmid: 20544136 |
| 7 |
Perkins GD, Brace S, Gates S. Mechanical chest-compression devices: current and future roles. Curr Opin Crit Care 2010; 16:203-210.
doi: 10.1097/MCC.0b013e328339cf59 pmid: 20463463 |
| 8 |
Handley AJ, Koster R, Monsieurs K, Perkins GD, Davies S, Bossaert L, et al. European Resuscitation Council guidelines for resuscitation 2005. Section 2. Adult basic life support and use of automated external defibrillators. Resuscitation 2005 ; 67:S7-23.
doi: 10.1016/j.resuscitation.2005.10.007 pmid: 16321717 |
| 9 |
Abella BS, Sandbo N, Vassilatos P, Alvarado JP, O'Hearn N, Wigder HN, et al. Chest compression rates during cardiopulmonary resuscitation are suboptimal: a prospective study during in-hospital cardiac arrest. Circulation 2005; 111:428-434.
doi: 10.1161/01.CIR.0000153811.84257.59 pmid: 15687130 |
| 10 |
Zuercher M, Hilwig RW, Ranger-Moore J, Nysaether J, Nadkarni VM, Berg MD, et al. Leaning during chest compressions impairs cardiac output and left ventricular myocardial blood flow in piglet cardiac arrest. Crit Care Med 2010; 38:1141-1146.
doi: 10.1097/CCM.0b013e3181ce1fe2 pmid: 20081529 |
| 11 |
Hightower D, Thomas SH, Stone CK, Dunn K, March JA. Decay in quality of closed-chest compressions over time. Ann Emerg Med 1995; 26:300-303.
doi: 10.1016/s0196-0644(95)70076-5 pmid: 7661418 |
| 12 |
Rubertsson S, Grenvik A, Zemgulis V, Wiklund L. Systemic perfusion pressure and blood flow before and after administration of epinephrine during experimental cardiopulmonary resuscitation. Crit Care Med 1995; 23:1984-1996.
doi: 10.1097/00003246-199512000-00007 pmid: 7497721 |
| 13 |
Harrison-Paul R. Resuscitation great. A history of mechanical devices for providing external chest compressions. Resuscitation 2007; 73:330-336.
doi: 10.1016/j.resuscitation.2007.01.002 pmid: 17383071 |
| 14 |
Kouwenhoven WB. The development of the defibrillator. Ann Intern Med 1969; 71:449-458.
doi: 10.7326/0003-4819-71-3-449 pmid: 4980234 |
| 15 |
O'Connor RE. The application of mechanical devices for CPR: make the first 5 minutes the best 5 minutes! Ann Emerg Med 2010; 56: 242-243. Epub 2010 Mar 31.
doi: 10.1016/j.annemergmed.2010.02.028 pmid: 20359772 |
| 16 |
Steen S, Liao Q, Pierre L, Paskevicius A, Sjöberg T. Evaluation of LUCAS, a new device for automatic mechanical compression and active decompression resuscitation. Resuscitation 2002; 55:285-299.
pmid: 12458066 |
| 17 |
Ong ME, Ornato JP, Edwards DP, Dhindsa HS, Best AM, Ines CS, et al. Use of an automated, load-distributing band chest compression device for out-of-hospital cardiac arrest resuscitation. JAMA 2006; 295:2629-2637.
doi: 10.1001/jama.295.22.2629 pmid: 16772626 |
| 18 |
Duchateau FX, Gueye P, Curac S, Tubach F, Broche C, Plaisance P, et al. Effect of the AutoPulse automated band chest compression device on hemodynamics in out-of-hospital cardiac arrest resuscitation. Intensive Care Med; 2010; 36:1256-1260.
doi: 10.1007/s00134-010-1784-x pmid: 20213073 |
| 19 |
Skogvoll E, Wik L. Active compression-decompression cardiopulmonary resuscitation: a population-based, prospective randomised clinical trial in out-of-hospital cardiac arrest. Resuscitation 1999; 42:163-172.
pmid: 10625156 |
| 20 | Hashimoto Y, Moriya F, Furumiya J. Forensic aspects of complications resulting from cardiopulmonary resuscitation. Leg Med (Tokyo) 2007; 9:94-99. |
| 21 |
Buschmann CT, Tsokos M. Frequent and rare complications of resuscitation attempts. Intensive Care Med 2009; 35:397-404.
doi: 10.1007/s00134-008-1255-9 pmid: 18807013 |
| 22 | Holper EM, Giugliano RP, Antman EM. Glycoprotein IIb/IIIa inhibitors in acute ST segment elevation myocardial infarction. Coron Artery Dis 1999; 53:618-622. |
| 23 |
Sunde K, Pytte M, Jacobsen D, Mangschau A, Jensen LP, Smedsrud C, et al. Implementation of a standardised treatment protocol for post resuscitation care after out-of-hospital cardiac arrest. Resuscitation 2007; 73:29-39.
doi: 10.1016/j.resuscitation.2006.08.016 pmid: 17258378 |
| 24 |
Rabl W, Baubin M, Broinger G, Scheithauer R. Serious complications from active compression-decompression cardiopulmonary resuscitation. Int J Legal Med 1996; 109:84-89.
doi: 10.1007/BF01355522 pmid: 8912053 |
| 25 |
Sunde K. All you need is flow! Resuscitation 2010; 81:371-372.
doi: 10.1016/j.resuscitation.2010.02.010 pmid: 20227003 |
| 26 |
Valk SD, Cheng JM, den Uil CA, Lagrand WK, van der Ent M, van de Sande M, et al. Encouraging survival rates in patients with acute myocardial infarction treated with an intra-aortic balloon pump. Neth Heart J 2011; 19: 112-118. Epub 2011 Jan 18.
pmid: 21475411 |
| 27 |
Wagner H, Terkelsen CJ, Friberg H, Harnek J, Kern K, Lassen JF, et al. Cardiac arrest in the catheterisation laboratory:A 5-year experience of using mechanical chest compressions to facilitate PCI during prolonged resuscitation efforts. Resuscitation 2010; 81:383-387.
doi: 10.1016/j.resuscitation.2009.11.006 pmid: 20007005 |
| 28 |
Black CJ, Busuttil A, Robertson C. Chest wall injuries following cardiopulmonary resuscitation. Resuscitation 2004; 63:339-343.
doi: 10.1016/j.resuscitation.2004.07.005 pmid: 15582770 |
| 29 |
Nielsen N, Sandhall L, Scherstén F, Friberg H, Olsson SE. Successful resuscitation with mechanical CPR, therapeutic hypothermia and coronary intervention during manual CPR after out-of-hospital cardiac arrest. Resuscitation 2005; 65:111-113.
doi: 10.1016/j.resuscitation.2004.11.007 pmid: 15797284 |
| 30 |
Agostoni P, Cornelis K, Vermeersch P. Successful percutaneous treatment of an intraprocedural left main stent thrombosis with the support of an automatic mechanical chest compression device. Int J Cardiol 2008; 124:e19-21.
pmid: 17336408 |
| 31 |
Ong ME, Annathurai A, Shahidah A, Leong BS, Ong VY, Tiah L, et al. Cardiopulmonary resuscitation interruptions with use of a load-distributing band device during emergency department cardiac arrest. Ann Emerg Med 2010; 56: 233-241. Epub 2010 Mar 12.
doi: 10.1016/j.annemergmed.2010.01.004 pmid: 20138401 |
| 32 |
Hallstrom A, Rea TD, Sayre MR, Christenson J, Anton AR, Mosesso VN Jr, et al. Manual chest compression vs use of an automated chest compression device during resuscitation following out-of-hospital cardiac arrest: a randomized trial. JAMA 2006; 295:2620-2628.
doi: 10.1001/jama.295.22.2620 pmid: 16772625 |
| 33 |
Smekal D, Johansson J, Huzevka T, Rubertsson S. No difference in autopsy detected injuries in cardiac arrest patients treated with manual chest compressions compared with mechanical compressions with the LUCAS device--a pilot study. Resuscitation 2009; 80: 1104-1107.s
doi: 10.1016/j.resuscitation.2009.06.010 pmid: 19595496 |
| [1] | Jing Yang, Hanqi Tang, Shihuan Shao, Feng Xu, Yangyang Fu, Shengyong Xu, Chen Li, Yan Li, Yang Liu, Joseph Harold Walline, Huadong Zhu, Yuguo Chen, Xuezhong Yu, Jun Xu. A novel predictor of unsustained return of spontaneous circulation in cardiac arrest patients through a combination of capnography and pulse oximetry: a multicenter observational study [J]. World Journal of Emergency Medicine, 2024, 15(1): 16-22. |
| [2] | Shuang Xu, Lang Guo, Weijing Shao, Licai Liang, Tingting Shu, Yuhan Zhang, He Huang, Guangqi Guo, Qing Zhang, Peng Sun. Vagus nerve stimulation protects against cerebral injury after cardiopulmonary resuscitation by inhibiting inflammation through the TLR4/NF-κB and α7nAChR/JAK2 signaling pathways [J]. World Journal of Emergency Medicine, 2023, 14(6): 462-470. |
| [3] | Gannan Wang, Zhe Wang, Yi Zhu, Zhongman Zhang, Wei Li, Xufeng Chen, Yong Mei. The neuro-prognostic value of the ion shift index in cardiac arrest patients following extracorporeal cardiopulmonary resuscitation [J]. World Journal of Emergency Medicine, 2023, 14(5): 354-359. |
| [4] | Shi-jiao Yan, Mei Chen, Jing Wen, Wen-ning Fu, Xing-yue Song, Huan-jun Chen, Ri-xing Wang, Mei-ling Chen, Xiao-tong Han, Chuan-zhu Lyu. Global research trends in cardiac arrest research: a visual analysis of the literature based on CiteSpace [J]. World Journal of Emergency Medicine, 2022, 13(4): 290-296. |
| [5] | Ryan W. Horton, Kian R. Niknam, Viveta Lobo, Kathryn H. Pade, Drew Jones, Kenton L. Anderson. A cadaveric model for transesophageal echocardiography transducer placement training: A pilot study [J]. World Journal of Emergency Medicine, 2022, 13(1): 18-22. |
| [6] | Alexei Birkun, Fatima Trunkwala, Adhish Gautam, Miriam Okoroanyanwu, Adesokan Oyewumi. Availability of basic life support courses for the general populations in India, Nigeria and the United Kingdom: An internet-based analysis [J]. World Journal of Emergency Medicine, 2020, 11(3): 133-139. |
| [7] | Jung Wan Kim, Jin Woong Lee, Seung Ryu, Jung Soo Park, InSool Yoo, Yong Chul Cho, Hong Joon Ahn. Changes in peak inspiratory flow rate and peak airway pressure with endotracheal tube size during chest compression [J]. World Journal of Emergency Medicine, 2020, 11(2): 97-101. |
| [8] | Ye-cheng Liu, Yan-meng Qi, Hui Zhang, Joseph Walline, Hua-dong Zhu. A survey of ventilation strategies during cardiopulmonary resuscitation [J]. World Journal of Emergency Medicine, 2019, 10(4): 222-227. |
| [9] | Israel Olatunji Gabriel, Joel O. Aluko. Theoretical knowledge and psychomotor skill acquisition of basic life support training programme among secondary school students [J]. World Journal of Emergency Medicine, 2019, 10(2): 81-87. |
| [10] | Alexei Birkun, Yekaterina Kosova. Social attitude and willingness to attend cardiopulmonary resuscitation training and perform resuscitation in the Crimea [J]. World Journal of Emergency Medicine, 2018, 9(4): 237-248. |
| [11] | Alexei Birkun, Maksim Glotov, Herman Franklin Ndjamen, Esther Alaiye, Temidara Adeleke, Sergey Samarin. Pre-recorded instructional audio vs. dispatchers’ conversational assistance in telephone cardiopulmonary resuscitation: A randomized controlled simulation study [J]. World Journal of Emergency Medicine, 2018, 9(3): 165-171. |
| [12] | Alexei Birkun, Maksim Glotov. Education in cardiopulmonary resuscitation in Russia: A systematic review of the available evidence [J]. World Journal of Emergency Medicine, 2017, 8(4): 245-252. |
| [13] | Ling Zhou, Hui Li, Hong-yan Wei, Chun-lin Hu, Xiao-li Jing, Hong Zhan, Xiao-xing Liao, Xin Li. Study on the development and usage of a cardiopulmonary resuscitation time point recorder [J]. World Journal of Emergency Medicine, 2017, 8(3): 195-199. |
| [14] | Chennappa Kalvatala Krishna, Hakim Irfan Showkat, Meenakshi Taktani, Vikram Khatri. Out of hospital cardiac arrest resuscitation outcome in North India — CARO study [J]. World Journal of Emergency Medicine, 2017, 8(3): 200-205. |
| [15] | Vinej Somaraj, Rekha P Shenoy, Ganesh Shenoy Panchmal, Praveen S Jodalli, Laxminarayan Sonde, Ravichandra Karkal. Knowledge, attitude and anxiety pertaining to basic life support and medical emergencies among dental interns in Mangalore City, India [J]. World Journal of Emergency Medicine, 2017, 8(2): 131-135. |
| Viewed | ||||||
|
Full text |
|
|||||
|
Abstract |
|
|||||